OpenBCM V1.07b12 (Linux)

Packet Radio Mailbox

DB0FFL

[Box DB0FFL]

 Login: GAST





  
G8MNY  > TECHNI   28.12.18 11:20l 73 Lines 3206 Bytes #999 (0) @ WW
BID : 51424_GB7CIP
Read: GAST
Subj: Drake WH7 QRO HF SWR Bridge
Path: DB0FFL<OE5XBL<F1OYP<IR2UBX<DB0RES<DB0ERF<OK0NAG<OK0NBR<OK2PEN<N3HYM<
      GB7CIP
Sent: 181228/1018Z @:GB7CIP.#32.GBR.EURO #:51424 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To  : TECH@WW

By G8MNY                                        (New Nov 06)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)

I have reverse engineered this QRO Bridge. It was quite straight forward.

SPECIFICATION                                       Ú==================¿
Frequency range  1.8-54MHz                          ³ ÚÄÄÄÄÄÄÄÄ¿       ³
Impedance        50ê                                ³ ³ \      ³   o   ³
Peak Power       2kW                                ³ ÃÄÄÄÄÄÄÄÄ´   _   ³
Connection      SO239                               ³  ~~~~~~~~   <_>  ³
Accuracy        ñ(5% of reading +1% of full scale)  ³__________________³
VSWR Insertion  1.05:1                                 ß             ß

THE CIRCUIT
    --------- HEAD UNIT -------
XMTR o)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄ(o LOAD
      ÃÄÄÄÄ=======  C1³/\  ³
      ³ T1 CCCCCCC   ===   ³
      ³    ³  ³  ³  /'³    ³
      ÃÄ´ÃÄ)ÄÄÁÄÄ)ÄÄÂÄÁÄ´ÃÄ´
      ³n15 ÃÄ68ÄÄ´  ³  n15 ³
      ³   _³_   _³_ ÀÄ2k2ÄÄ´      ----------- METER BOX -------
      ³ D1\_/   \_/D2      ³   wh  R \~ ~ ~ ~ ~ ~ \      ___ 200uA
      ³    ³     ÃÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄo \    VAR Úo  \   +/SWR\640ê
      ³    ³     ³         ³   bn    <ÄÄoÄÄ68kÄ´ <ÄÄoÂÄ<Meter>¿
      ³    ÃÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄo      SWR Ào    ³  \___/ ³
      ³    ³     ³         ³   gn  F      2000W      À´ÃÄÄÄÄÄÄ´
      ³    ÃÄ68kÄ)Ä20kPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo      10n    ³
      ³    ³     ³         ³   bl          200W               ³
      ³    ÃÄ10kÄ)Ä20kPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo             ³
      ³    ³     ³         ³   rd           20W               ³
      ³    ÃÄÄÄÄÄ)Ä10kPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo             ³
      ³ 1n===   ===1n      ³   bk                             ³
      ÀÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

HOW IT WORKS
A short length of thick egoes through the screened ferrite transformer T1
making a 1 turn primary, & the lead joins the XTMR & LOAD sockets together. A
pickoff voltage attenuator is formed with trimmer C1 & the 2 150pF caps. This
RF voltage is fed to T1 secondary centre tap. Load current is transformed by T1
into a voltage across the 5W non inductive 68ê.

When the load is exactly 50ê the diode D2 sees no RF as the voltage sample &
the current sample are in opposition & cancel dependent on the calibration of
the trimmer C1.

The 2k2 is needed to complete the DC meter circuit & will affect the
calibration of the lowest frequency, as will the L value of T1.

Diode D1 however sees the voltage tap & the current sample added together &
produces DC across the 1nF, & feeds this to the meter box on the brown wire for
SWR full scale, & via the calibration power presets on green, blue & red wires.

SWR voltage readings will be present on D2 when the load is not exactly 50ê are
fed out on the white wire.

The meter box has a 1 wafer switch that forms a 2 switch bank connected as
show, to give all the functions.


See also my Tech buls on "A Homebrew HF SWR Bridge", "PEP Meter modification",
"QRP SWR Bridge", "Meter Damping & Speed Up" & "Palstar AT1500CV ATU", "HF ATU
& SWR Bridge VC300LP/QT-1"


Why Don't U send an interesting bul?

73 de John, G8MNY @ GB7CIP



Lese vorherige Mail | Lese naechste Mail


 26.11.2024 03:39:01lZurueck Nach oben