G8MNY  > TECHNI   18.01.22 09:04l 62 Lines 2602 Bytes #999 (0) @ WW
BID : 58630_GB7CIP
Read: GAST
Subj: Battery Backup PSU
Path: DB0FFL<OE2XZR<OE5XBL<DB0RBS<DB0RES<PI8CDR<LU4ECL<JE7YGF<GB7CIP
Sent: 220118/0755Z @:GB7CIP.#32.GBR.EURO #:58630 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To  : TECH@WW

By G8MNY                                           (New Sep 07)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)

Here is my design for a backup PSU suitable for a repeater etc. It offers a
different approach to just paralleling up a battery with a PSU. 

FEATURES
  Trickle charges battery @ 14.2V boost or 13.5V normal @ up to 1A peak.
  A flat battery does not hold repeater off air/blow up PSU.
  LED indicator shows "battery present" when mains is on.

CIRCUIT

   Fuse                    +20V  _____
  Äo-oÄ¿   ÚÄÄÂÄÄÄÄ´>ÃÄÄÂÄÄÂÄÄÄÄ´13.8VÃÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄ¿ ______Tx Power
        )º(   ÃÄ´<ÃÄÄ¿  ³  ³+   ³ Reg ³ +³100u         /Relay   1-3A
MAINS   )º(   ³      ³  ³ ===    ~~³~~  ===          ÚÙ
        )º(   ³Bridge³  ³  ³10mF   ³     ³           ³
        )º(   ³ Ú´<ÃÄÁÄÄ)ÄÄÁÂÄÄÄÄÄÄÁÂÄÄÄÄÁÄÄ0V       ³
  ÄÄÄÄÄÙ   ÃÄÄ)ÄÁÄÄÄ´>ÃÄÙ __³__  u1 ³ u1        boost³
       15V ³  ³          ³relay³ Ú´ÃÅĴÿ      ÚÄo/ÄÄ´
        4A ³  ÀÄÄ´>ÿ     ~~³~~  ³ _³__ ³  D7  ³     ³
           ÀÄÄ´>ÃÄÄÄÁÄÄÄÄÄÂÄÁÄÄÄÄÁ´7815ÃÁÄÄ´>ÃÄÁÄ´>ÃÂÁÄÄo-oÄ +Battery
              D5   D6     e\³   in ~~~~out       D8 ³  Fuse
                         PNPÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ68kÄÄÄÄÄÙ
                           /³
                          ÀÄÄÄÄÄ1k5ÄÄ´>ÃÄÄÄ0V
D5-8 1N4002                          || LED
Main regulator &                Mains & Battery
7815 on heatsink                   Present

OPERATION
The +13.8V PSU is quite conventional as needed, but with the addition of D5 &
D6 supplies raw DC power to the mains fail relay, which connects the battery
instead of the PSU when it is released. Extra "no drop out diodes" could be
placed across the relay contacts if absolutely no power break is required
e.g. to feed a uProcessor PCB.

This raw DC is also used to charge & maintain the lead acid battery. The charge
voltage is either 1 or 2 diode drops less than the 15V regulator output as
needed.

On the battery going flat after a long mains failure for example, the 15V
regulator limits the battery recovery current to 1 amp (why it needs to be
heatsinked), which stops the battery from taking down the PSU, so the repeater
will come back on as soon as mains is restored even on a shorted battery.

N.B. This is the opposite to some strategies (UPS) that wack in full current
into the battery in case of another power failure.

The LED battery indicator shows the presence of the battery when the battery
voltage is less than the raw DC rail voltage by turning on the PNP transistor.



Why Don't U send an interesting bul?

73 De John, G8MNY @ GB7CIP


Lese vorherige Mail | Lese naechste Mail


 24.11.2024 17:20:42lZurueck Nach oben