G8MNY > TECHNI 17.02.21 09:23l 75 Lines 3022 Bytes #999 (0) @ WW
BID : 23757_GB7CIP
Read: GAST
Subj: A Homebrew HF SWR Bridge
Path: DB0FFL<DB0FHN<DB0RBS<DB0ERF<DB0RES<ON0AR<VE2PKT<PY2BIL<OK2PEN<GB7CIP
Sent: 210217/0816Z @:GB7CIP.#32.GBR.EURO #:23757 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To : TECH@WW
By G8MNY (New May 09)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
For up to 30MHz this is a rebuild of standard C.B. "ELECT marc" 2 meter SWR
bridge. Instead of the original frequency sensitive pick up lines that are OK
for 27MHz, it uses a ferrite ring transformer for the current & a resistive tap
for the voltage.
FEATURES
5W 50W 500W Power meter ranges.
Separate single SWR meter with full scale Set pot.
RF field strength detector (used separately).
CIRCUIT
Tx Coax 1:26 transformer Ant
o)Ä)===========================================ÂÄÄ(o
ÃÄÙ ::::::: ÚÄÄÄ´ ³
³ _____())))))_____ 10k 10k ³
³ ³ 26T ³ ÃÄÄÄÙ ³
³ ÃÄÄ68RÄÄÄÂÄÄÄ68RÄÄ´ ³ ³
³ ³ ÃÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÙ ³ Field
³ Sch_³_ ³ _³_ ³ Strength
³ \_/ ³ \_/ ³ Aerial
³ 1n ³ ³ ³ 1n ³ \|/
ÃÄÄÄÄ´ÃÄÄÄÄÄÄÄÄÄÄÂÁÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄ¿ ÃÄÄÄÄÄÄÄ´ÃÄÄÄ´ |
³ ³ ³ Foro oRef ³ |
³ ÚÄÄÄ¿500W ÃÄÄÄÄ¿+ ³ /³\ ³ |
³Cal4 220k o === Power ³ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄ)ÄÄÂÄ´<ÃÄÂo
³ ÃÄÄÄo50W ³1n Meter ³ Set SWR ³ ³ _³_
³Cal3 100k o<ÄÄÄÄÁÄÄÄÄÙ ÚÄÁÄ¿ SWR<ÄÄÂÄMeter¿ ³ ³ /_\
³ ÃÄÄÄÙ5W 3k3 ³ 220k ===1n ³ ³ ===1n ³
³Cal2 50k Cal1³ 390 log ÀÄÄÄÄÄÄ´ ³ ³ ³
ÀÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÁÄÁÄÄÁÄÄÄÄÄÙ
Both Meters are 25uA & 1500ê.
The 10Ks are 1W carbon type.
The 390R is carbon type.
Both 68R are 0.5W carbon type.
Diodes are Schottky or Germanium types.
PRINCIPLE
The 50ê coax goes through a small HF ferrite 15mm torroidal with a 26 turn
secondary, the coax outer is grounded only at one end so 1/26 of the inner
current appears across the series 68Rs. The centre of these is connected to a
preset voltage attenuator so that with a 50R load the reverse signal cancels.
The forward power is measured via 3 series presets into a separate meter.
For SWR the Forward & Revers signals are measured via the adjustable pot to the
SWR meter.
For the field strength a small aerial is screwed in & the disconnected SWR
meter can now show local RF fields. (e.g. along your coax outer!)
CALIBRATION (done in order as they affect each other!)
Cal1. set Reverse SWR null reading on a good load
Cal2. set 5W full scale deflection
CaL3. set 50W full scale deflection
Cal4. set 500W full scale deflection.
N.B. the meters have square law power scales & an SWR scale.
See also my Tech buls on "Drake WH7 QRO HF SWR Bridge",
"PEP Meter modification", "QRP SWR Bridge","QRO 1kW HF Metered Dummy Load",
"HF ATU & SWR Bridge VC300LP/QT-1" & "Meter Damping & Speed Up".
Why don't U send an interesting bul?
73 De John, G8MNY @ GB7CIP