I have been investigating how a very old 1MHz Frequency Counter/Timer works. It
is all done with Germanium PNPs & no ICs! And it uses 4x 2.5cm tall projected
number displays, as it was made before Nixi tubes & LEDs!

 ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿    INPUT           0.1-1V 100kê//60pF
 ³  _____________            Ü    ³    FREQUENCY Range 1Hz-1.2MHz ñ1 count
 ³ ³ [] [] [] [] ³   /~~\       ß ³         Gate times 1S 10mS 1ms 100uS 10uS
ɵ ³ [] [] [] [] ³  ³    ³        Æ»   PERIOD          0.1uS-99.99mS
º³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÙ   \__/         ³º        Prescalers 1:1 1:10 1:100
º³                ø ø     ß  O  O ³º   COUNT           0-9999 repeating
º ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ º   Ref Output      100kHz 1V
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ   Supply 115/230V or 12V dc (+ case!)

SCHEMATIC
        ÚÄÄÄÄÄÄ¿ÚÄÄÄÄÄÄ¿      ÚÄÄÄÄ¿        ÚÄÄÄÄÄÄÄÄ¿              ÚÄÄÄÄÄÄÄÄÄ¿
InputÄo/´PreampôBufferÃ>¿  Ú>´GateÃ>¿   ÚÄ>´1s CountÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´0-9 Meter³
      o ÀÄÄÄÄÄÄÙÀÄÄÄÄÄÄÙ ³  ³ ÀÄÄÂÄÙ ³   ³  ÀÂÂÄÄÄÄÄÄÙ              ÀÄÄÄÄÄÄÄÄÄÙ
  Test³                  |  |    |   |   |   ³³Overflow
      ³   =======M O D E  S W I T C H====== >´³ ÚÄÄÄÄÄÄÄÄ¿          ÚÄÄÄÄÄÄÄÄÄ¿
      ³   |   |     |     | |     |     | |  ³À>´10 CountÃÄÄÄÄÄÄÄÄÄÄ´0-9 Meter³
Ref<ÄÄÁÄÂTB  TB    TB    TB ³    TB    TB ³  ³  ÀÂÂÄÄÄÄÄÄÙ          ÀÄÄÄÄÄÄÄÄÄÙ
        ³     ³     ³     ³ ³     ³     ³ ³  ÃÄÄÄÙ³Overflow
ÚÄÄÄÄÄÄ¿³ÚÄÄÄ¿³ÚÄÄÄ¿³ÚÄÄÄ¿³ ³ÚÄÄÄ¿³ÚÄÄÄ¿³ ³  ³    ³ ÚÄÄÄÄÄÄÄÄÄ¿     ÚÄÄÄÄÄÄÄÄÄ¿
³100kHzÃÁ´ö10ÃÁ´ö10ÃÁ´ö10ÃÙ À´ö10ÃÁ´ö10ÃÙ ³  ³    À>´100 CountÃÄÄÄÄÄ´0-9 Meter³
³ Osc  ³ ³10k³ ³ 1k³ ³100³   ³10 ³ ³1Hz³  ³  ³      ÀÂÂÄÄÄÄÄÄÄÙ     ÀÄÄÄÄÄÄÄÄÄÙ
ÀÄÄÄÄÄÄÙ ÀÄÄÄÙ ÀÄÄÄÙ ÀÄÄÄÙ   ÀÄÄÄÙ ÀÄÄÄÙ  ³  ÃÄÄÄÄÄÄÄÙ³Overflow
      Time Base TB       Time/Prescaller  ³  ³        ³ ÚÄÄÄÄÄÄÄÄÄÄ¿ÚÄÄÄÄÄÄÄÄÄ¿
                     ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³  ³        À>´1000 Countô0-9 Meter³
                     ³Display Hold TimerÃ>Ù  ³Resets    ÀÂÄÄÄÄÄÄÄÄÄÙÀÄÄÄÄÄÄÄÄÄÙ
                     ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ    ÀÄÄÄÄÄÄÄÄÄÄÄÙ
HOW IT WORKS
The large MODE SWITCH can rearrange the units to COUNT continuously, Gated with
a TimeBase for FREQUENCY, or count a TimeBase gated with the input for PERIODS.

The display timer (Manual or about 2 seconds) starts the process off, clears
down the counters & enables the timer gate.

Each counter & divider circuit uses 8 transistor in 4 bistables as binary
ripple counters they are wired to reset @ 10 & overflow to the next counter or
divider.

Each display digit consists of a meter with 0-9 number shadow mask & lamp. The
DC drive for these uses 4 resistor (72k 36k 18k & 9k) from each binary stage of
the BCD counter output, such that the meter current represents the number 0-9.

 _      Continiously
³ À¿_     Counting  
     À¿_   Signal      1 digit,  10x slower for 2nd
        À¿_                      100x slower for 3rd
           À¿_³                  1000x slower for 4th.

External presets are used to calibrate scale & zero each meter (0 & 9 test
buttons provided).

For PERIOD measurement, it rewires the units, to counts the 100kHz & uses the
last 2 ö10s fed from the input frequency, to give of the input gates of 1x 10x
or 100x that period. This results in measurements of 10x 1x 0.1x in uS.

PSU
This is -7.5V for the electronics & a raw -10V regulated for the 4 lamps.

IN USE
Despite being very old it still all works & is very easy to read. The 4 digit
readout might seem to be a limitation, but overflow counting is possible. So to
measure say 1.250895MHz you 1st read the 1250kHz & then alter the range to see
the 0895Hz.

For low frequencies like CTCSS tones, where 1/10 of Hz resolution is needed,
then Period measurement & a calculator comes into its own.


See other tech buls "Watson 'Hunter' Counter Mods", "PIC Freq Counter Mods",
"Marconi Counter Type 2434A", "198kHz Off Air Standard", "Off Air Lock for Ref